A medical computer monitor, often referred to as a monitor, is an instrument capable of measuring the biological signals of a patient's physiological and pathological states, extracting their characteristics and converting them into visual information. It is one of the most popular medical instruments in clinical applications and plays a vital role especially in emergency, operating theatres and ICUs.
一. Main Functions
Through various functional modules, the monitor can detect the human body's ECG signal, heart rate, oxygen saturation, blood pressure, respiratory rate and body temperature and other important parameters in real time. This information is crucial for doctors because they provide a comprehensive view of the patient's current physiological state, which helps them make correct diagnostic and therapeutic decisions. At the same time, the monitor also has a supervisory alarm function. When one of the patient's physiological parameters exceeds the preset safety range, the monitor will send out an alarm to remind healthcare workers to deal with it in time.

二.Working Principle
The working principle of the monitor is mainly based on the acquisition and processing of biomedical signals. The system converts biomedical signals into electrical signals through the signal detection and pre-processing module, and carries out pre-processing such as interference suppression, signal filtering and amplification. Then, it samples, quantifies, and calculates and analyses each parameter through the data extraction and processing module. Finally, the resultant data are stored to RAM in real time and can be transmitted to PC in real time, where the value of each parameter and the change of waveform can be displayed in real time.

三.Precautions for use
- Before using the monitor, it should be ensured that the instrument has good performance and the accessories such as electrode sheets and wires are complete. At the same time, it is necessary to check whether the patient's skin is clean and dry to ensure that the electrode sheet can be closely affixed and accurately collect signals. 2.
- When placing the electrode pads, the wires of the electrode pads should be correctly connected to the monitor according to the identification. At the same time, it should be ensured that the position of the electrode sheet is accurate, avoiding pressure and pulling to ensure the accuracy of monitoring.
- When setting alarm parameters, they should be set according to the patient's condition and the doctor's recommendation. The alarm parameters should be set neither too sensitive to cause frequent false alarms nor too sluggish to delay the treatment of the condition.
4. During continuous observation, healthcare workers should pay close attention to the parameters and waveform changes on the monitor, record and report to the doctor in time. At the same time, the electrode sheet position should be changed regularly to avoid skin damage or inaccurate signal acquisition.